Hyperstrada 821 2013, 45200 km.
The bike do not start at all.
Earlier it start when the engine was cold. If it then stoped, not possible to start again.
At last I found that compression was 4 bar at front cylinder and 6 bar at rear cylinder.
Checking the valve clearance, all intake has 0.00. Should be 0.10 mm at minimum.
I did valve adjustment/check at 28300 km at a Ducati shop.
At this time the valve clearance should have been min 0.10 mm on the intake.
During 17000 km, the vale clearance har gone from 0.10 mm to 0.00 mm!!
According to scheduled maintenance the valve should be checked every 30000 km.
Has anyone else experienced the same phenomenon?
//Stefan
The bike do not start at all.
Earlier it start when the engine was cold. If it then stoped, not possible to start again.
At last I found that compression was 4 bar at front cylinder and 6 bar at rear cylinder.
Checking the valve clearance, all intake has 0.00. Should be 0.10 mm at minimum.
I did valve adjustment/check at 28300 km at a Ducati shop.
At this time the valve clearance should have been min 0.10 mm on the intake.
During 17000 km, the vale clearance har gone from 0.10 mm to 0.00 mm!!
According to scheduled maintenance the valve should be checked every 30000 km.
Has anyone else experienced the same phenomenon?
//Stefan